产品展示首页 > USCN & cloud-clone 试剂盒 & 抗体 & 蛋白 > USCN & ELISA试剂盒 > 酶联免疫试剂盒/elisa试剂盒(夹心法)
恶性脑肿瘤缺失蛋白1(DMBT1)检测试剂盒(酶联免疫吸附试验法)
货    号:
USCN-SEJ251Mu
规    格:
96wells
品    牌:
Uscn
英文名称: ELISA Kit for Deleted In Malignant Brain Tumors 1 (DMBT1)
基因别称: GP340; SAG; Muclin; Glycoprotein 340; Hensin; Salivary agglutinin; Surfactant pulmonary-associated D-binding protein
实验步骤: 1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
检测范围: 0.156-10ng/mL
最低检测限: The minimum detectable dose of this kit is typically less than 0.056ng/mL
适应生物: Mus musculus (Mouse)
样本: tissue homogenates, cell lysates and other biological fluids
实验时长: 3h
种类: Double-antibody Sandwich
特异性:

This assay has high sensitivity and excellent specificity for detection of Deleted In Malignant Brain Tumors 1 (DMBT1).
No significant cross-reactivity or interference between Deleted In Malignant Brain Tumors 1 (DMBT1) and analogues was observed.

精度:

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Deleted In Malignant Brain Tumors 1 (DMBT1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Deleted In Malignant Brain Tumors 1 (DMBT1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

稳定性:

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

实验原理: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Deleted In Malignant Brain Tumors 1 (DMBT1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Deleted In Malignant Brain Tumors 1 (DMBT1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Deleted In Malignant Brain Tumors 1 (DMBT1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Deleted In Malignant Brain Tumors 1 (DMBT1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
产品应用: Enzyme-linked immunosorbent assay for Antigen Detection.
应用备注: 48T, 96T, 96T×5, 96T×10, 96T×100
期货: 5-7天
运输条件: 蓝冰运输
保存条件: 按要求4度和-20度分开保存
有效期: 12个月
限制: 仅用科研 ( ONLY USE R&D research )
需自备的设备及试剂: 450nm酶标仪 & 移液器等